EasyManua.ls Logo

Kohler Industrial Generator Set - Appendix B Programmer-Defined Settings

Kohler Industrial Generator Set
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TP-6694 7/18 Appendix 109
Appendix B Programmer-Defined S ettings
Use the table below to record programmer-defined
settings during the generator set controller setup and
calibration. The controller default settings and ranges
provide guidelines. The table contains all faults with
ranges and time delays including items that do not have
adjustments. Some notices give the programmer a
choice to make them active Not adjustable
programmer-defined settings result when the controller
logic does not allow changes or the values are engine
limited.
SiteTecht setup software is required for programming the
controller. Contact your local distributor/dealer for assistance.
Note: Inhibit time delay is the time delay period after
crank disconnect.
Note: The engine ECM may limit the crank cycle even if
the controller is set to a longer time period.
Programmer -Defined Settings
Description
Controller Display
Message
Write
Access
Display
Si
teTech
GenSet
Mode
Always
R
unning
S
topped
Range
Setting
Default
Selection
Time
Delay
Range
(sec.)
Default
Time
Delay
(sec.)
Programmer-
Defined
Settings
Engine Functions
Critically high fuel level
(diesel-powered models only) *
Fuel Level Critically
High
0--100% 95% 0--10 5
ECM communications loss ECMCommErr
Shutdwn
Fixed 10 Not adjustable
ECM diagnostics (multiple
inputs) [
ECM xxxxxx Warning Not adjustable
ECM diagnostics (multiple
inputs) [
ECM xxxxxx Shutdwn Not adjustable
ECM faults (address conflict) ECM Addr Err
Shutdwn
Not adjustable
ECM faults (model mismatch) ECM Mismatch
Shutdwn
0--255 0
Engine over speed Eng S peed High
Shutdwn
S A 105--120% 115%
Engine RPM
(manual speed adjust)
Version 3.10.3 or higher
Engine RPM Display DS A
60 Hz:
1751--1849
50Hz:
1451--1549
60 Hz:
1800
50 Hz:
1500
Engine start aid active Starting Aid Notice
Engine under speed Eng Speed Low
Shutdwn
S A 75--95% 85%
Fuel tank leak * Fuel Leak Warning Not adjustable
Fuel tank leak * Fuel Leak Shutdwn Not adjustable
High battery voltage Battery High Warning S A 110--135% 125% Fixed 10 Not adjustable
High coolant temperature
Coolnt Temp High
Warning
0--10
(0--30
inhibit)
5
(0
inhibit)
High coolant temperature
Coolnt Temp High
Shutdwn
0--10
(0--30
inhibit)
5
(0
inhibit)
High fuel level (diesel-powered
models only) *
Fuel Level High
Warning
0--100% 90% 0--10 5
Loss of fuel Loss of fuel Not adjustable
Low battery voltage Battery Low Warning S A 80--105% 100% Fixed 90 Not adjustable
Low coolant level * Coolant Lvl Low
Shutdwn
Fixed 5 Not adjustable
Low coolant temperature
Coolant Temp Low
Warning
Fixed
16_C
(60_F)
0--10
(0--30
inhibit)
5
(0
inhibit)
Low cranking voltage Lo Crank Vlt Warning Fixed 60% Fixed 6 Not adjustable
Low engine oil level * Oil Level Low Warning Not adjustable

Table of Contents