AS-11.65.037
37 (40) (A) 2009-10-16
KDL16
Maintenance Instruction
© 2009 KONE Corporation
All rights reserved.
Disclosure prohibited
D.1.2 LWD mode (P-LM3D-022, or older, or not marked)
Zero calibration (“TARE”):
Display shows “TARE”.
Press P button.
Make zero setting with empty car by selecting “YES”.
Press P. (The display blinks and beeps for 5 sec.)
Sensor configuration:
Select “CCP” (well known weight).
Press P.
Add 100% of the rated load to the car.
Set the elevator rated load (kg) by pressing the arrow buttons (the same load as
above).
Press P.
Number of passengers:
Set the maximum number of persons in the car using arrow buttons.
Press P.
Roping ratio:
Select roping 1:1 or 2:1 using arrow buttons.
Press P.
Alarm values:
Display shows “AL 1” .
Press P
Set the rated load of the elevator using arrow buttons.
Press P.
Display shows “AL 2”.
Press P.
Set the rated load of the elevator using arrow buttons.
Press P.
Display shows “AL 3”.
Press P.
Set 120% of the rated load of the elevator using arrow buttons.
Press P.
Compensation chain weight (“CHAI”):
Display shows “CHAI”.
Press P.
Select “NO” using arrow buttons.
Press P.
Car indicator (“INDI”):
Display shows “INDI”
Press P.
Select “NO” using arrow buttons.
Press P.
Analogical output (“CURR”):
Display shows “CURR”
Press P.
Select “4-20” using arrow buttons.
Press P.
Rated load of the elevator is displayed.