6.2 Replacing tachometer with encoder for MX machines
19 Open the landing door. Keep the landing
door open by using door blocking device.
Only MRL elevators
Step Action Illustration/Note
1 Open the tachometer fixing screws (4 pcs.).
Remove installation cover, if applicable. It is
not needed in encoder assembly.
Do not remove the tachometer cable,
because encoder cable will be mounted on
it.
2 Fit the encoder carefully to the machine.
Install the fixing screws (4 pcs.).
3 Route the encoder cable to the drive
module.
Fix the encoder cable to the tachometer
cable by using cable ties.
NOTICE: Do not shorten the encoder
cable.
Step Action Illustration/Note

Table of Contents