7-78 BA 35203_04 * 3.0 * 35203_04_07_Wartung.fm
7 Maintenance
Monitoring of the exhaust after-treatment
Monitoring of the diesel particulate filter (DPF) (optional)
Fig. 301
G
66
1
2
3
Symbol in
field G
Function Result
No symbol appears in the field G
of the digital display.
Normal operating conditions
The soot load is in the permissible range.
Symbol G/1 illuminates
permanently.
Increased soot load
Automatic regeneration in operation.
Machine operation can be continued.
Diesel engine operated with increased speed.
Symbol G/2 flashes.
Caution! The soot load is in the high range
Automatic regeneration is no longer possible.
Perform manual regeneration on the next occasion
see “Manual regeneration” on page 7-84.
Symbol G/2 flashes.
Warning light 66
lights up.
A short acoustic warning
sounds.
Caution! Critical soot load
Diesel engine goes into protective functions and
performance is reduced by 30%.
Perform manual regeneration immediately
see “Manual regeneration” on page 7-84.
Symbol G/3 flashes.
Warning light 66
lights up.
A continuous acoustic warning
sounds.
Caution! Soot load too high
Diesel engine goes into protective functions and
performance is reduced by 30%.
Diesel engine speed is limited to 1200 rpm.
Manual regeneration is no longer possible.
The diesel particulate filter has to be replaced by an
authorized service center
see “Cleaning/replacing the diesel particulate filter
(option)” on page 7-86.
1
2
66
2
66
3

Table of Contents