8-14 BA 35203_04 * 3.0 * 35203_04_08_Betriebsstoerung.fm
8 Malfunctions
8.5 Malfunctions in the air conditioning system (option)
Information
Repairing, filling up and emptying the air conditioning system may be
performed only by an authorized service centre!
Malfunctions in the air conditioning system (option)
Malfunctions Possible causes Remedy
See
page
Fan does not run
Malfunctioning or loose fuse Replace fuses 7-50
Interrupted line
Contact an authorized service
centre
Malfunctioning fan motor
Malfunctioning fan switch
Fan cannot be switched off
Short circuit in cable or fan
switch
Reduced fan output
Dirty contacts
Very dirty heat exchanger Clean the heat exchanger 7-55
Insufficient heating output or none
at all
Flow temperature too low
Contact an authorized service
centre
Malfunctioning thermostat
Dirty heat exchanger fins Clean the heat exchanger 7-55
Loss of refrigerant on equipment
Loose hose connection
Contact an authorized service
centre
Damaged hose
Damaged heat exchanger
Compressor does not run
Interruption in solenoid coil of
compressor
V-belt pulley does not turn even
though magnetic clutch is
applied
Compressor clutch slips
Malfunctioning controls
Torn V-belt
Loose V-belt Retension the V-belt 7-42