BA 35203_04 * 3.0 * 35203_04_08_Betriebsstoerung.fm 8-15
Malfunctions 8
Condensor overflow
Expansion valve is stuck in open
position
Contact an authorized service
centre
Iced-up evaporator
Thermostat sensor in wrong
position
Malfunctioning expansion valve
or thermostat
Clogged condensor Dirty radiator fins Clean the condensor 7-55
Loss of refrigerant
Interruption of refrigerant line
Contact an authorized service
centre
System leak
Insufficient refrigerating output
Clogged fan duct
Refrigerant level too low
Humidity in system
System cools with interruptions
Line interruption, insufficient
ground connections or loose
contacts in solenoid coil of
compressor
Contact an authorized service
centre
Malfunctioning fan motor
Very loud system
Loose or excessively worn V-belt 7-42
Loose compressor bracket
or worn inside parts of the
compressor
Excessive wear of fan motor
System overfill
Not enough refrigerant in the
system
Malfunctions in the air conditioning system (option)
Malfunctions Possible causes Remedy
See
page