BA 35203_04 * 3.0 * 35203_04_07_Wartung.fm 7-91
Maintenance 7
Applying the anticorrosion protection
Bear in mind the following instructions as you apply the anticorrosion
protection:
• Carefully cover all fastening surfaces and elements to which the
anticorrosive protection may not be applied
– see “Components coated with anticorrosive wax” on page 7-89.
• Apply Elaskon products with a brush or commercially available spray
equipment.
• The protective Elaskon coating can be removed with an Elaskon
cleanser if necessary.
• Spots are difficult to remove from clothing.
• Affix a “Wet paint!” or a similar sign to newly coated machines.
Treatment of oxidised surfaces
If in spite of all precautionary measures some components should be
affected by corrosion (oxidized), treat the oxidized area follows:
Electric connections
• Remove the remaining protective wax at the oxidized area with an
Elaskon cleanser.
• Treat the affected areas with an oxide cleanser, for example with
Elaskon Multi 80.
• Apply Elaskon Multi 80 to the contact surfaces of the plug-and-socket
connection.
• Establish the connection.
• Apply/spray the anticorrosion protection onto the electric connection
from all sides.
Sheet-metal parts
• Remove the remaining protective wax at the oxidized area with an
Elaskon cleanser.
• Remove all remaining corrosion and paint coating from the affected
area down to the bare material, otherwise the protective coating will
not adhere properly.
• Clean the affected area with a cleaning solvent, and apply a 2-
component prime coating and then a 2-component paint coating to it.
• Then preserve the area with the anticorrosion protection.