8-12 BA 35203_04 * 3.0 * 35203_04_08_Betriebsstoerung.fm
8 Malfunctions
517005 VCU: Controller temperature too low
Non-critical error
Machine can continue to be
operated. Have error rectified
by an authorized service
centre when the opportunity
arises.
517006 Hydraulic oil temperature sensor error
517008 Error can. receipt CCVS1 message
517009 Error can. receipt EEC1 message
517030 Error can. receipt IC1 – intake air temperature sensor
517056 Error can. receipt IC1 - intake air temperature sensor
517906 Power supply
517907 CAN BUS
518960 Release switch – parking brake
518974 Differential lock – differential lock push button
518979
Quickhitch lock/unlock control circuit III – push button/scroll
wheel
518980
518982
Highflow 2 (continuous function of control circuit III) – switch
(continuous function of control circuit III)
518983 Error can. receipt of selected travel direction
518984 Travelling drive – RWD scroll wheel
518988 Scroll wheel error of telescope/4th control circuit
518989 Hydraulic quickhitch – release switch (quichhitch unlocking)
518993 Load stabilizer – load stabilizer switch
518994 Logic error of lifting arm when lowering
518996 Tilt ram lock – tilt-ram lock switch
519005
Highflow 1 (control circuit IV/raise tipping trailer) – switch
(control circuit IV)
519007 Water separator error
519015 Travelling drive – neutral push button
519016
Front socket/bucket repositioning – push button (front socket/
bucket repositioning)
519019 Raise/lower tipping trailer – switch (raise/lower tipping trailer)
519034
Release switch – switch (control circuit III/lock for long-haul
travel)
519046 Travelling drive manual throttle (joystick signal 1 S097)
519050 Additional function 2 – switch (additional function 2)
519051
Plunger switch (front/rear additional control circuit) – plunger
switch (front ball-type cock)
519053 Operator-presence switch error
519066 Additional function 1 – push button (additional function 1)
Overview of error codes for work hydraulics
Error code Possible causes Remedy