BA 35203_04 * 3.0 * 35203_04_04_Inbetriebnahme_01.fm 4-25
Putting into operation 4
Putting the immobilizer out of operation
We recommend putting the immobilizer out of operation, for example if the
machine has to stay in a service centre or if the machine does not require
any protection. This avoids having to communicate the code.
1. Disable the system by entering the personal or main code and by
confirming with the (*) key.
2. Turn the ignition key to position “1”.
The LED illuminates for 2 seconds.
3. As soon as the LED goes out, press the (*) key for about 2 seconds
until a short acoustic signal, followed by two further signals, sounds.
The LED now flashes very slowly, and the keypad is disabled.
4. Turn the ignition key to the zero position and remove it.
The engine can be started without entering the code. The system is
out of service even if electric power is interrupted.
Information
If the system is out of operation, the LED flashes slowly even if the ignition
key is in position 1.
Entering the personal or main code does not have the effect of putting the
system back into operation again (the acoustic signals for confirmation are
still given). See the following procedure (“Putting the immobilizer back into
operation again”) to leave the out-of-operation status again.
Putting the immobilizer back into operation again
1. Turn the ignition key to position (0).
2. Press the (*) key 2 seconds until two short acoustic signals sound.
3. The system is now re-activated; The code has to be entered again to
start the engine.