Audio Flash Memory Upgrade
36
10 Audio Flash Memory Upgrade
The VP-728 audio firmware is located in FLASH memory, which lets you
upgrade
1
Downloading from the Internet (see section
to the latest Kramer firmware version in minutes! The process
involves:
10.1)
Connecting the PC to the AUDIO PROG. terminal block connector (see section
10.2)
Upgrading Firmware (see section
10.3)
10.1 Downloading from the Internet
You can download the up-to-date file
2
1. Go to our Web site at
from the Internet. To do so:
www.kramerelectronics.com and download the file:
FLIP_VP728.zip” from the Technical Support section.
2. Extract the file: “FLIP_VP728.zip” to a folder (for example, C:\Program
Files\Kramer Flash).
3. Create a shortcut on your desktop to the file:FLIP.EXE”.
10.2 Connecting the PC to the RS-232 Port
Before installing the latest Kramer audio firmware version on a VP-728 unit,
do the following:
1. Connect the PC to the AUDIO PROG. terminal block connector, as defined
in
Figure 20 and Table 19:
RS-232 PINOUT
Rx
GND
1
2
3
4
5
6
7
8
9
Tx
Figure 20: RS-232 PINOUT Connection
1 Upgrade should be carried out by skilled technical personnel. Failure to upgrade correctly will result in the malfunction of
the machine
2 The files indicated in this section are given as an example only. File names are liable to change from time to time