VP-728 Communication Protocol
56
Control Type
Function Parameter Description
Set
Get
0 1 105 512~3071 Advance Input Mode: HT
0 1 106 32~(HS-48) Advance Input Mode: HW
0 1 107 80~(HT-HA-12) Advance Input Mode: HS
0 1 108
640~1920
<= (HT-92)
Advance Input Mode: HA
0 1 109
0: Negative polarity
1: Positive polarity
Advance Input Mode: HP
0 1 110 384~2047 Advance Input Mode: VT
0 1 111 2~(HS-13) Advance Input Mode: VW
0 1 112 15~(VT-VA-1) Advance Input Mode: VS
0 1 113
480~1200
<= (VT-16)
Advance Input Mode: VA
0 1 114
0: Negative polarity
1: Positive polarity
Advance Input Mode: VP
0 1 115 25 < OCLK < 165 Advance Input Mode: OCLK(Integer)
0 1 116 25 < OCLK < 165 Advance Input Mode: OCLK(Decimal)
0 1 117
0: Off
1: On
Advance Input Mode: Enable
0 - 118 N/A Advance Input Mode: Save
0 1 119 512~3071 Advance Output Mode: HT
0 1 120 32~(HS-48) Advance Output Mode: HW
0 1 121 80~(HT-HA-12) Advance Output Mode: HS
0 1 122
640~1920
<= (HT-92)
Advance Output Mode: HA
0 1 123
0: Negative polarity
1: Positive polarity
Advance Output Mode: HP
0 1 124 384~2047 Advance Output Mode: VT
0 1 125 2~(HS-13) Advance Output Mode: VW
0 1 126 15~(VT-VA-1) Advance Output Mode: VS
0 1 127
480~1200
<= (VT-16)
Advance Output Mode: VA
0 1 128
0: Negative polarity
1: Positive polarity
Advance Output Mode: VP
0 1 129 25 < OCLK < 165 Advance Output Mode: OCLK(Integer)
0 1 130 25 < OCLK < 165 Advance Output Mode: OCLK(Decimal)
0 - 131 N/A Advance Output Mode: Save
0 - 132 N/A Advance Output Mode: Set Current
0 - 133 N/A Volume Up
0 - 134 n/a Volume Down
0 1 135
0: Follow Output
1: Follow Input
HDCP Setting
0 1 136
0:Custom1
1:Custom2
2:Custom3
3:Custom4
Advance Input Mode: Custom Input