To set display auto-sleep entry no AV signal is detected:
1. In the Navigation pane, click Video & Audio Settings.
2. Next to “5V Power off timeout” click Enabled. The timeout field beneath the button is
enabled.
Figure 36: Video & Audio Settings – 5V Power Off Timeout
3. Under “When all video signals are lost, delay 5V power off for" set the delay time from
30-60,000 seconds (where 900 is the default).
Display auto-sleep entry timeout is set.
Managing EDID
VS-411XS enables copying EDID data to either one or several inputs (for use by the
connected sources) from the following EDID sources:
• Inputs
• Output
• Default EDID
• Custom EDID data file
When the status of an EDID changes on the device (caused by outputs being exchanged),
the display is not updated automatically. In the browser, click Refresh to update the display.
An input must be connected to the device to read the EDID from a connected output. If a
video signal is not detected on the input, the output is disabled and the EDID cannot be read.