Set signal type on
input/output.
“Set” command is not
available for all devices
(refer to device
specifications).
COMMAND
#SIG-TYPEio_mode,io_index,signal_src<CR>
FEEDBACK
~nn@SIG-TYPEio_mode,io_index,signal_src<CR><LF>
io_mode – Input/Output
0 – Input
1 – Output
io_index – Number that indicates the
specific input or output port:
1-N (N= the total number of input or
output ports)
signal_src – Signal type
0 – No signal
1 – DVI
2 – HDMI
3 – DisplayPort
4 – HDBaseT
5 – SDI
6 – VGA
7 – Follow output
8 – DGKat
Set signal type on
input/output:
#SIG-TYPE1,1,1<CR
>
Get device serial
number.
COMMAND
#SN?<CR>
FEEDBACK
~nn@SNserial_num<CR><LF>
serial_num – 14 decimal digits,
factory assigned
Get the device serial
number:
#SN?<CR>
Get firmware version
number.
COMMAND
#VERSION?<CR>
FEEDBACK
~nn@VERSIONfirmware_version<CR><LF>
firmware_version – XX.XX.XXXX
where the digit groups are:
major.minor.build version
Get the device firmware
version number:
#VERSION?<CR>