Lumio service manual
77
FINAL TESTS
3. Insert capsule holder with dummy
capsule and test device p. 72.
4. Insert water tank.
5. Place a container under test device.
6. Plug in resp. switch ON coffee
machine.
7. When machine is ready, set bar
display to level 7 with selector wheel.
8. Push selection lever to right position
“HOT”. Machine starts rinsing.
Risk of injury!
Hot water
splashes can escape
during the leakage
test. Wear safety
glasses for the
inspection.
9. Close pressure control valve progres-
sively to reach Pmax (11.5 - 14.5 bar
if possible).
10. Turn selection lever to middle posi-
tion "STOP"
11.
Perform a visual inspection of all
components under pressure (hose
connections, capsule holder).
STOP