FINAL TESTS
12. After inspection, release remaining
pressure by opening the pressure
control valve completely.
If no leak could be detected, repeat the
leakage check with cold water:
13. Set bar display back to level 7 with
selector wheel.
14. When machine is ready, push selec-
tion lever to left position “COLD”.
Machine starts rinsing.
15. Close pressure control valve progres-
sively to reach Pmax (11.5 - 14.5 bar
if possible).
16. Turn selection lever to middle posi-
tion "STOP"
17.
Perform a visual inspection of all
components under pressure.