COOLING SYSTEM 16
115
K01212-12
Main work
– Place an appropriate container under the water pump cover.
–
Remove screw
1
. Take off radiator cap
2
.
– Completely drain the coolant.
–
Mount and tighten screw
1
with a new seal ring.
Guideline
Screw, water pump
cover
M6 10 Nm (7.4 lbf ft)
– Position the motorcycle upright.
– Completely fill the radiator with coolant.
Coolant ( p. 144)
S04312-10
–
Loosen screw
3
and wait until coolant escapes without bub-
bles.
–
Mount and tighten screw
3
.
Guideline
Bleeder screw, cylin-
der head
M6 10 Nm (7.4 lbf ft)
– Completely fill the radiator with coolant.
Coolant ( p. 144)
S04311-10
–
Mount radiator cap
2
.
Danger
Danger of poisoning Exhaust gases are toxic and inhal-
ing them may result in unconsciousness and death.
– Always make sure there is sufficient ventilation
when running the engine.
– Use effective exhaust extraction when starting or
running the engine in an enclosed space.
– Allow the engine to warm up and cool down again.
Finishing work
– Check the cooling system for leaks.
– Check the coolant level. ( p. 112)