EasyManua.ls Logo

KUHN PROPUSH 2000 Series - Hardened Tips; Electric Flow Control; Manual Flow Control; Sequence Valve

KUHN PROPUSH 2000 Series
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PROPUSH 2000 SERIES
42
8. - Optional equipment
7N018KUS_A
Box Spreader Trailer Type
8.4 Hardened tips
Kit no. 18967743
Units with vertical beaters have the option of
hardened steel beater tips for better durability and
use with more abrasive materials.
Vertical beater tooth bolt torque should be 135 ft lbs
dry. Vertical beater tooth bolts should be checked
after the first few loads and re-torqued if necessary.
Torque should be checked on a monthly basis.
8.5 Electric flow control
Kit no. 18964811
The electric flow control allows control of the pusher
speed from the tractor. This is used when the tractor
does not have flow controls built in.
8.6 Manual flow control
Kit no. 18964810
The manual flow control that is mounted on the unit
allows control of the pusher speed. This is used
when the tractor does not have flow controls built in.
8.7 Sequence valve
Kit no. 18967444 - 2044 Only
Kit no. 18967446 - 2054 Only
The sequence valve package affects the operation
of the endgate and pusher. When the sequence
valve is installed, the endgate must be completely
raised before the pusher will begin operating.
Without the sequence valve, the operator must
follow this sequence manually.

Related product manuals