FS-9120DN/9520DN
1-6-27
(5) Detaching and refitting the operator panel PWB
Follow the procedure below to detaching and refitting the operator panel PWB.
Procedure
1. Insert a flat-blade screwdriver or the like into
the clearance and remove the operation
panel cover.
Figure 1-6-56
2. Remove the four screws and the connector
and then remove the operator panel unit.
Figure 1-6-57
3. Remove eight screws and then remove the
operator panel PWB.
4. Replace the operator panel PWB and refit all
the removed parts.
Figure 1-6-58
Operator panel cover
Operator panel unit
Operator panel PWB