2M8/2M9-1
1-5-33
11. Remove two screws.
12. Release three hooks and then remove
the wire holder.
Figure 1-5-49
13. Remove six connectors (YC36, YC32,
YC102, YC101, YC107,YC108) and
FFC (YC8) from the main PWB.
Figure 1-5-50
Wire holder
Hook
Hook
Hook
Screw
Screw
YC36 YC32 YC8
YC102
YC101
YC107
YC108
Main PWB
Main PWB