2JL/2JJ/2JG/2JD-1
1-3-101
U927
Clearing the all copy counts and machine life counts (one time only)
Description
Resets all of the counts back to zero.
Supplement
The total account counter and the machine life counter can be cleared only once if all count values are 1000
or less.
Method
1. Press the start key.
2. Press [EXECUTE].
3. Press the start key. All copy counts and machine life counts are cleared.
CANNOT EXECUTE is displayed if the count cannot be cleared.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
U928
Checking machine life counts
Description
Displays the machine life counts.
Purpose
To check the machine life counts.
Method
Press the start key. The current machine life counts is displayed.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
U930
Checking/clearing the charger roller count
Description
Displays the counts of the charger roller counter for checking or clearing.
Purpose
To check the count after replacement of the charger roller unit.
To clear the counter value when replacing the charger roller unit.
Method
Press the start key. The current counts of the charger roller count for each color is displayed.
Clearing
1. Press the reset key.
2. Press the start key. All counts are cleared.
Setting
1. Enter seven-digit value using the numeric keys.
2. Press the start key. The value is set.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
U972
Setting the type of high voltage unit
Description
Identifies transfer high voltage PWB 2 to be old or new
Purpose
Changing settings are not required.
Setting
1. Press the start key.
2. Select the item to be set.
3. Change the setting value using the cursor up/down keys.
4. Press the start key. The setting is set.
5. Turn the main power switch off and on.
Maintenance
item No.
Description
Display Description Setting range
2nd Transfer HV Identifies transfer high voltage PWB 2 A (old)/B (new)