EasyManua.ls Logo

Kyocera TASKalfa 3050ci - Page 134

Kyocera TASKalfa 3050ci
936 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2LK/2LN/2LM/2LC-2
1-3-40
U039 Adjusting the magnification
Description
Adjusts the magnification of the printing.
Purpose
Make the adjustment if the magnification in the auxiliary scanning direction is incorrect.
Caution
Adjust the magnification in the following order.
Method
1. Press the start key.
2. Press the system menu key.
3. Press the start key to output a test pattern.
4. Press the system menu key.
5. Select the item to be adjusted.
Adjustment: [Sub Scan]
1. Change the setting value using the +/- keys or numeric keys.
Increasing the setting makes the image longer, and decreasing it makes the image shorter.
Figure 1-3-6
2. Press the start key. The value is set.
Completion
Press the stop key. The indication for selecting a maintenance item No. appears.
Item No. Description
U039
U065
(P.1-3-52)
U070
(P.1-3-57)
Display Description
Setting
range
Initial
setting
Change in
value per step
Sub Scan Magnification in the auxiliary
scanning direction
-1 to 1 0 0.1 %
350 ± 1.4 mm

Table of Contents

Other manuals for Kyocera TASKalfa 3050ci