2LK/2LN/2LM/2LC-2
1-4-23
6500 DF bundle discharge sensor
non arrival jam
DF bundle discharge sensor (DFBDS) does not
turn on within specified time of DF middle eject
sensor (DFMES) turning on.
K
6510 DF bundle discharge sensor
stay jam
DF bundle discharge sensor (DFBDS) is not turned
off since the bundle discharge starts (4000-sheet
finisher).
K
6511 DF bundle discharge sensor (DFBDS) is not turned
off since the bundle discharge starts (1000-sheet
finisher).
K
6600 DF drum sensor non arrival
jam
DF drum sensor (DFDRS) does not turn on within
specified time of DF paper entry sensor (DFPES)
turning on.
K
6610 DF drum sensor stay jam DF drum sensor (DFDRS) is not turned off within
specified time of its turning on.
K
6710 Center folding unit stay jam During paper conveying to center folding unit, DF
drum sensor (DFDRS) is not turned off within spec-
ified time of its turning on.
K
6810 DF side registration sensor 1
stay jam
DF side registration sensor 1 (DFSRS1) is not
turned off within specified time after driving the DF
side registration motor 1 (DFSRM1) (4000-sheet
finisher).
K
6811 DF side registration sensor 1 (DFSRS1) is not
turned off within specified time after driving the DF
side registration motor 1 (DFSRM1) (1000-sheet
finisher).
K
6910 DF side registration sensor 2
stay jam
DF side registration sensor 2 (DFSRS2) is not
turned off within specified time after driving the DF
side registration motor 2 (DFSRM2) (4000-sheet
finisher).
K
6811 DF side registration sensor 2 (DFSRS2) is not
turned off within specified time after driving the DF
side registration motor 2 (DFSRM2) (1000-sheet
finisher).
K
7000 DF staple operation error DF staple sensor (DFSTS) is not turned on within
specified time after driving the DF staple motor
(DFSTM) (4000-sheet finisher).
K
7001 DF staple sensor (DFSTS) is not turned on within
specified time after driving the DF staple motor
(DFSTM) (1000-sheet finisher).
K
7100 CF paper entry sensor non
arrival jam
CF paper entry sensor (CFPES) is not turned on
even if a specified time has elapsed after the
machine eject signal was received.
K
Code Contents Conditions
Jam
location*
*: Refer to figure 1-4-1 for paper misfeed indication (see page 1-4-1).