2LK/2LN/2LM/2LC
2-3-19
YC6
34 MPF_CL O 0/24 V DC MPPFCL: On/Off
Connected to
feed PWB 1
35 MPF_LIF2 O 0/24 V DC MPLM: On/Off
36 MPF_LIFT1 O 0/24 V DC MPLM: On/Off
37 GND - - Ground
38 TC_MOT_LOCK - - Not used
39 TC_TONER_LED - - Not used
40 TC_TONER_FUL
L
- - Not used
41 TC_TONER_VCO
NT
- - Not used
42 INTER_LOCK - - Not used
43 DU2_PD O 0/3.3 V DC DUM2 control signal
44 DU2_CLK O 0/3.3 V DC (pulse) DUM2 clock signal
45 DU2_REM(CL_L
OW)
O 0/3.3 V DC DUM2/DUCL2: On/Off
46 GND - - Ground
47 DU_OPEN I 0/3.3 V DC DUCSW: On/Off
48 DU_FAN - - Not used
49 PRESS_MOT_RE
M1
O 0/24 V DC TRRM: On/Off
50 PRESS_MOT_RE
M2
O 0/24 V DC TRRM: On/Off
51 PRESS_RLS_SE
NS
I 0/3.3 V DC TRRS: On/Off
52 DU_SENS I 0/3.3 V DC DUS2: On/Off
53 BELT_JAM_SENS - - Not used
54 GND - - Ground
55 CLN_SOL_RET O 0/24 V DC CLSOL: On/Off (RET)
56 CLN_SOL_REM O 0/24 V DC CLSOL: On/Off (ACT)
57 REG_SENS_R_S I Analog IDS2 detection signal
58 REG_SENS_R_P I Analog IDS2 detection signal
59 REG_R_LED O Analog IDS2 control signal
60 GND - - Ground
61 REG_SENS_F_S I Analog IDS1 detection signal
62 REG_SENS_F_P I Analog IDS1 detection signal
63 REG_F_LED O Analog IDS1 control signal
64 GND - - Ground
Connector Pin Signal I/O Voltage Description