83
* Extinguish any open flame.
* Evacuate all persons from the vehicle.
* Shut off the gas supply at the propane container or
source.
* Do not touch any electric switch or use any phone or radio in
the vehicle.
* Do not start the vehicles engine or electric generator.
* Contact the nearest gas supplier or qualified service
technician for repairs.
* If you cannot reach a gas supplier or qualified service
technician, contact the nearest fire department.
* Do not turn on the gas supply until the gas leak (s)
has been repaired.
C. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any
gas control which has been under water.
Operating Instructions
1. Before using furnace , it s suggested to open entrance door and
windows to air out camper for any unusual odors such as propane.
2. Be sure propane bottle has fuel and valve is open.
3. Release thermostat from “OFF position and onto HEAT
position.
4. Set temperature to 5 degrees above room temperature.
5. Blower will start in 0-15 seconds ,run for 30 seconds during heat
chamber PURGE cycle , removing any propane out if any.
6. Second cycle, blower continues to run, module board will: (a)
send spark to burner tube, (b) open valve in control to release
propane to burner tube.
7. Ignition attempt will be for 7 seconds.
8. Failing to ignite, board will make 2 more attempts and go into
lockout if it fails.
9. Drop thermostat down to lowest setting, wait 1 minute and repeat
steps 4 to 7. Air in line prevents burner from lighting.
10.After burner lights, set thermostat to desired temperature.
11. To shut burner down ,move thermostat to lowest setting.
12. Blower will continue to run for about 2 minutes until heat is
removed from chamber.
Note: There is a switch on furnace to shut off 12 volt DC power.
Furnace will not operate on: OFF” position.