NOTE: If the furnace should lock-out, the blower will go off in 2 to 5
minutes and remain off until unit is reset by reactivating
thermostat. See #8.
NOTE: These operating instructions will vary depending on the
furnace size and model. Refer to the furnace manufacture
information manual in your unit for the complete furnace
operating instructions, for you unit.
TO TURN OFF PROPANE TO APPLIANCE
1. Set the thermostat to lowest setting, then move lever or switch
to “OFF” position.
2. Turn off all electric power to the appliance if service is to be
performed.
External Vents. Always be sure these vents are clear of any objects
like screens, duct tape, et
Ducting. Wall or floor registers, and return air grills MUST be kept
clear of any obstructions. Any such restrictions will prevent the
furnace from full operation. Closeable registers will reduce air flow.
Never shut registers off completely, possibly causing furnace to limit
out and shut down.
Gas pressure, as defined in Chapter Four - Systems, is extremely
important. A dial gauge or U-tube manometer is required to perform
tests and adjustments. Pressure must be set at 11 inches WC.
(water column) plus or minus 1/2 inch. Incorrect gas pressure can
cause any appliance to operate inconsistently and cause poor
Do not install screens over the vents for any reason. Screens will become
restricted and cause unsafe furnace operation. Accessories are being mar-
keted for RV products which we do not recommend. For your safety, only
factory authorized parts are to be used on your furnace.