Operation
OPTIONS
The OPTIONS menu gives access to the amplied controller general settings:
delay unit (ms, meters, feet or samples)
LCD screen contrast
LED and screen backlight mode
spanning tree
reset to default factory settings
‽OPTIONS ‼※
IP SETTINGS
OK
‽DELAY UNIT ‼※
ms
‽SCREEN CONTRAST ‼※
80%
‽LED & BACKLIGHT MODE ‼※
NORMAL
‽SPANNING TREE ‼※
OFF
‿RESET TO FACTORY ‼※
DEFAULT SETTINGS?
DELAY UNIT
Delay values can be displayed in ms (milliseconds), meters, feet or samples. The values in meters and feet are given for a
temperature of 20° C / 68° F.
OK
‽DELAY UNIT ‼※
ms
DELAY UNIT
>ms<
‽DELAY UNIT ‼※
SAMPLES
+ OK
Procedure
1. From the main menu, select OPTIONS.
2. Press the OK key or the encoder wheel to validate.
3. Turn the encoder wheel to select DELAY UNIT.
4. Press the OK key or the encoder wheel to validate.
5. Turn the encoder wheel to select the value.