EasyManua.ls Logo

L-Acoustics LA4X - Clear Group Params

L-Acoustics LA4X
83 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
Saving preset parameters
Preset parameter modications are not automatically saved and are lost if the preset is reloaded.
Refer to STORE PRESET (p.37).
Resetting the preset parameters
All preset parameters (including preset name) can be reset to the default values.
OK OK
‿RESET PRESET ‼※
ARE YOU SURE?
OUTPUTS MUTED!
011:K2 70 100
LF_A LF_A MF_A HF_A
Procedure
1. From the main menu, select PRESET PARAMETERS.
2. Turn the encoder wheel to select RESET PRESET.
3. Press the OK key or the encoder wheel to validate.
The amplied controller displays ARE YOU SURE? OUTPUTS MUTED!.
4. Press the OK key or the encoder wheel to validate (or the ESC key to cancel).
Resetting the parameters of a user preset (stored in memory space 001 to 010) only affects the current
parameters.
To reset the parameters of a stored preset, overwrite the memory space after resetting the preset. Refer to
STORE PRESET (p.37).
CLEAR GROUP PARAMS
Group parameters (names, gains, delays, contour EQs) are dened in LA Network Manager and cannot be accessed
from the amplied controller. They remain active when the amplied controller is disconnected from the computer
running LA Network Manager (in standalone mode), and when the amplied controller is shut down or restarted. Group
parameters are not preset-dependent and remain active when a different preset is loaded.
Therefore, L-Acoustics recommends to clear group parameters when an amplied controller is used in standalone mode
after being used within a network.
To verify if output channels are assigned to a group, refer to Displaying input level, input selection, input mode and group
information (p.33).
CLEAR GROUP PARAMS does not clear the preset parameters. Refer to PRESET PARAMETERS (p.38)
clearing the group parameters
OK OK
‽CLEAR GROUP PARAMS ‼※
INPUT SETTINGS
ARE YOU SURE?
OUTPUTS MUTED!
011:K2 70 100
LF_A LF_A MF_A HF_A
Procedure
1. From the main menu, select CLEAR GROUP PARAMS.
The amplied controller displays L-NET ACTIVE. CANNOT CLEAR when the amplied controller is
connected to the L-NET network. Group parameters cannot be cleared when the amplied controller is
remotely controlled by LA Network Manager.
Press the ESC key to cancel.
The amplied controller displays NO GROUP DEFINED. CANNOT CLEAR when the amplied controller is
not assigned to any group.
Press the ESC key to cancel.
2. Press the OK key or the encoder wheel to validate.
The amplied controller displays ARE YOU SURE? OUTPUTS MUTED!.
3. Press the OK key or the encoder wheel to validate (or press the ESC key to cancel).
40 LA4X owner's manual (EN) version 14.1

Table of Contents

Other manuals for L-Acoustics LA4X

Related product manuals