Operation
MONITORING & INFO
The MONITORING & INFO menu provides real-time measurements and information on the amplied controller:
For each output channel:
real-time RMS output voltage (in percentage of the maximum value supported by the connected transducer
section)
output temperature (in percentage of the operating range)
Ethernet ports and AVB clock current status.
Version numbers of the amplied controller onboard rmware and preset library.
Amplied controller's MAC address and hardware version.
The ENCLOSURE CHECK function.
‽MONITORING & INFO ‼※
OPTIONS
OK
‾SPK HANDLING (%) ‼
12% 10% 13% 11%
‽OUT CH TEMP (%) ‼
52% 53% 50% 48%
‽ETHERNET LINKS ‼
1: 1G FULL 2:100 FULL
‽AVB CLOCK STATUS ‼
DISABLED
‽FIRMWARE ‼
V2.8.1
‽PRESET LIBRARY ‼
V5.8
‽MAC ADDRESS ‼
00:1B:92:01:90:3A
‽HARDWARE INFO ‼
ID4
‿ENCLOSURE CHECK ‼
PRESS OK TO START
SPK HANDLING (%)
SPK HANDLING (%) (speaker handling) displays the RMS voltage measured at each individual amplier circuit output as
a percentage of the maximum voltage supported by the connected speaker section.
‾SPK HANDLING (%) ‼
12% 10% 13% 11%
For example in this illustration, the RMS voltage of channels OUT 1 to OUT 4 is respectively 12, 10, 13, and 11% of the
maximum values.