Specications
Digital input
Supported operating mode
Standard AES/EBU (AES3) or electrical S/PDIF (IEC 60958 Type II)
Sampling frequency (Fs) 44.1, 48, 64, 88.2, 96, 128, 176.4 or 192 kHz
Word length 16, 18, 20, 24 bits
Sample Rate Converter (SRC)
Sampling frequency 96 kHz (SRC referenced to the amplied controller internal clock)
Word length 24 bits
Dynamic range 140 dB
Distortion THD+N < -120 dBFS (dB Full Scale)
Bandpass ripple ±0.05 dB (20 Hz - 40 kHz, 96 kHz)
Input gain
Range -12 dB to 12 dB
Steps 0.1 dB
Latency
Analog and AES/EBU
In standard operating mode 3.84 ms (independent from input Fs)
In low latency operating mode 0.84 ms (independent from input Fs)
LA4X owner's manual (EN) version 14.1 75