List of AVB reservation errors
code error resolution
7 Reported latency has changed A device on the network is behaving incorrectly.
Disconnect and reconnect the stream.
Reboot the talker.
Reboot the bridges on the path from the talker to the listener.
If the talker supports manual conguration of the stream parameters,
congure the stream to use another Stream ID.
8 Egress port is not AVB capable Temporarily displayed when a network cable is disconnected then
reconnected.
If displayed for more than a few seconds, it indicates one of the switch in the
network is non-AVB capable, or is congured incorrectly.
Only use AVB-capable bridges on the path from the talker to the listener.
If the bridges support conguration of the SR Class priority, congure all
the bridges with the same setting (default is 3 for Class A streams).
9 Use a different dest. address One of the bridges on the path from the talker to the listener has used all of its
internal resources.
If the talker supports manual conguration of the stream parameters,
congure it to use another destination MAC address.
Try to reboot the talker to make it use another MAC address.
Disconnect some already reserved streams.
10 Out of MSRP resources One of the bridges on the path from the talker to the listener has reached its
limits.
Try to disconnect some streams.
Try to reboot the bridges on the path from the talker to the listener.
11 Out of MMRP resources One of the bridges on the path from the talker to the listener has reached its
limits.
Try to disconnect some streams.
Try to reboot the bridges on the path from the talker to the listener.
12 Cannot store dest. addr. One of the bridges on the path from the talker to the listener has reached its
limits.
Try to disconnect some streams.
Try to reboot the bridges on the path from the talker to the listener.
13 Req. priority is not an SR class The talker is behaving incorrectly, or the switches conguration has changed
while the stream was active.
Disconnect and reconnect the stream.
Reboot the talker.
14 Max frame size too big for
media
The talker is behaving incorrectly.
Disconnect and reconnect the stream.
Reboot the talker.
15 MSRP fan-in ports limit reached One of the bridges on the path from the talker to the listener has AVB ports
usage limitation and has reached its limits.
If possible, change the conguration of the bridges to allow more
simultaneous usage of AVB ports.
Review the network cabling to use less ports on the limiting bridge(s).
16 Changed rst value for reg.
stream ID
A device on the network is behaving incorrectly.
Disconnect and reconnect the stream.
Reboot the talker.
Reboot the bridges on the path from the talker to the listener.