ESI-2000
Pilot’s Guide 1-17
Description
BATTERY
INDICATORS
DESCRIPTION
Charging Indicators
Battery requires charging but is unable due to low
or high temperature conditions. The discharge
function of the battery continues to work depending
on current SOC. Battery will begin to charge when
temperature is within 0°C to 45°C (32°F to 113°F).
NOTE: The interior of the ESI-2000 can be 10°C to
15°C (18°F to 27°F) warmer than the exterior.
Battery is currently charging and has a SOC
15%.
Battery is currently charging and has a SOC > 15%
but 40%. NOTE: As the battery ages, the charging
indicator remains amber at a SOC of 50%, 75% or
100%.
Availability Indicators
The accuracy of the battery capacity meter may
be degraded and requires a calibration discharge
cycle. Until a capacity calibration is performed, the
discharge function of the battery continues to work
but the battery capacity is not available.
Battery operation (discharge) is not possible due
to high temperature conditions or very low battery
voltage. Battery discharge functionality returns to
normal when temperature is less than 60°C (140°F)
or when internal battery voltage charges to a usable
level.
The battery failed indicator is shown if an
unrecoverable failure of the battery system is
detected. The battery charge and discharge
functions are unavailable.