Gem Enclosure Firmware
Status Severity Alarm State
Low Warning Temperature Alert Warning S1
High Warning Temperature Alert Warning S1
Over Temperature Alarm Fault - Critical S1
I
2
C Bus failure Fault - Loss of redundancy S1
EM Card Interface Module Fault Fault - Critical S1
Drive Power Control Fault Warning - No loss of drive power S1
Drive Power Control Fault Fault - Critical - loss of drive power S1
Drive Removed Warning None
Insufficient Power Available Warning None
Intrusion < 5 min Warning S1
Intrusion > 5 min Fault - Critical S4
For all of these alarm conditions, the Ops Panel LED will show a fault.