5: Configuration Using Web Manager
UDS2100 Device Server User Guide 35
communication to the UDS2100 unit. The Telnet Com Port
Cntrl feature is used in conjunction with the Com Port
Redirector (CPR) utility. (See the CPR online Help for details.)
Terminal Name
This field is available for configuration only when Telnet Com
Port Cntrl is set to Enable.
Use the terminal name for the Telnet terminal type. Enter only
one name. When this option is enabled, the unit also reacts to
the end of record (EOR) and binary options, which can be
used for applications such as terminal emulation to IBM hosts.
Connect Response
A single character is transmitted to the serial port when there
is a change in connection state. The default setting is None.
Use Hostlist
If this option is set to Yes, the device server scrolls through
the host list until it connects to a device listed in the host list
table. Once it connects, the unit stops trying to connect to any
others. If this connection fails, the unit continues to scroll
through the table until it connects to another IP in the host list.
The host list is disabled for Manual Mode and for Modem
Mode. The unit will not accept a data connection from a
remote device when the host list option is enabled.
LED
Select Blink for the status LEDs to blink upon connection or
None for no LED output. The default setting is Blink.
Disconnect Mode
On Mdm_Ctrl_In Drop
Set to Yes for the network connection to or from the serial port
to disconnect (drop) when Modem Control In transitions from
an asserted state to not asserted state. The default setting is
No.
Hard Disconnect
When set to Yes, the TCP connection closes even if the
remote site does not acknowledge the disconnect request.
Check EOT (Ctrl-D)
Select Yes to drop the connection when Ctrl-D or Hex 04 is
detected. Both Telnet Com Port Cntrl and Check EOT
(Ctrl+ D) must be enabled for Disconnect with EOT to
function properly. Ctrl+D is only detected going from the serial
port to the network. The default setting is No.
Inactivity Timeout
Use this parameter to set an inactivity timeout. The unit drops
the connection if there is no activity on the serial line before
the set time expires. Enter time in the format mm:ss, where m
is the number of minutes and s is the number of seconds. To
disable the inactivity timeout, enter 00:00.
3. When you are finished, click the OK button.
4. On the main menu, click Apply Settings.

Table of Contents

Other manuals for Lantronix UDS2100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix UDS2100 and is the answer not in the manual?

Lantronix UDS2100 Specifications

General IconGeneral
Isolation1.5 kV
CertificationFCC, C/UL, CSA, VCCI, CE, TUV, CTick
Serial interface typeRS-232/422/485
Serial ports quantity2
Ethernet LAN data rates10, 100 Mbit/s
Electrostatic Discharge (ESD) protection15 kV
USB 2.0 ports quantity0
Supported network protocolsARP, UDP, TCP, ICMP, Telnet, TFTP, AutoIP, DHCP, HTTP, SNMP TCP, UDP, Telnet, TFTP, RFC2217
Built-in processorLantronix DSTNI-EX
Processor frequency48 MHz
Compatible operating systemsWindows 98/ME/NT/2000/XP
Flash memory2 MB
RAM capacity0.256 MB
LED indicatorsLAN, Y
Storage temperature (T-T)-40 - 85 °C
Operating temperature (T-T)0 - 60 °C
Operating relative humidity (H-H)10 - 90 %
Input voltage9 - 30 V
Weight and Dimensions IconWeight and Dimensions
Weight400 g
Dimensions (WxDxH)72 x 23 x 95 mm