B
brownkyleSep 6, 2025
What to do if Lantronix Server appears set up correctly but isn't communicating across the network?
- DDaniel FloresSep 6, 2025
If the Lantronix device server appears to be set up correctly, but you are not communicating with your device across the network, ensure the serial port settings are correct and verify you are connecting to the correct socket of the device server. Also, the device server may not be set up correctly to make a good socket connection to the network. You can check the socket connection by observing CP1 (if configured for LED1 functionality). If CP1 blinks consistently or is completely off, there is a good socket connection. If CP1 is low, use Connect Mode option C0 for connections from the network to the device server, or C1 or C5 for connections from the device server to the network. See the full list of Connect Mode options in Connect Mode.