7: 59BSetup Mode: Channel Configuration
XPort® Device Server User Guide 62
DisConnTime (Inactivity Timeout)
Use this parameter to set an inactivity timeout. The unit drops the TCP connection to the local
port if there is no activity on the serial line before the set time expires. Enter time in the format
mm:ss, where m is the number of minutes and s is the number of seconds.
DisConnTime (0: 0) ?:
To disable the inactivity timeout, enter 00:00. Range is 0 (disabled) to 5999 seconds (99
minutes, 59 seconds). Default is 0.
Send Characters
Enter up to two characters in hexadecimal representation in sendchar.
SendChar 1 ( 0) ? _
SendChar 2 ( 0) ? _
If the unit receives a character on the serial line that matches one of these characters, it
sends the character immediately, along with any awaiting characters, to the TCP connection.
This action minimizes the response time for specific protocol characters on the serial line (for
example, ETX, EOT). Setting the first sendchar to 00 disables the recognition of the
characters. Alternatively, the unit can interpret two characters as a sequence (see
Pack Control on page 60).
Telnet Terminal Type
This parameter displays only if you enabled the terminal type option in Disconnect Mode.
With this option enabled, you can use the terminal name for the Telnet terminal type. Enter
only one name.
With terminal type option enabled, the unit also reacts to the EOR (end of record) and binary
options, useful for applications like terminal emulation to IBM hosts.
Channel (Port) Password
This parameter appears only if the channel (port) password option is enabled in Disconnect
Mode. With this option enabled, you can set a password on the serial port.