8: Setup Mode: Advanced Settings
XPort® Device Server User Guide 66
Minimum notification interval
The minimum time allowed between individual triggers. If a trigger
event occurs within the minimum interval since the last trigger, it is
ignored.
Re-notification interval
Indicates the time interval at which a new email message is sent to
the recipient(s) when a single trigger event remains active.
Trigger 2
Refer to Trigger 1 for details on completing these fields.
Note: Each trigger is independent of the others. Each condition within an individual trigger
must be met before the unit sends the email.
Trigger 3
Refer to Trigger 1 for details on completing these fields.
Note: Each trigger is independent of the others. Each condition within an individual trigger
must be met before the unit sends the email.
Expert Settings (Option 5)
Note: You can change the Enable alternate MAC setting using telnet or serial connections
only. It is not available through the Web Manager.
CAUTION: Only an expert should change these parameters. You must definitely
know the consequences the changes might have.
Figure 8-2. Expert Settings
TCP Keepalive time in s (1s - 65s; 0s=disable): (45) ?
ARP Cache timeout in s (1s - 600s) : (600) ?
CPU performance (0=Regular, 1=Low, 2=High): (0) ?
Disable Monitor Mode @ bootup (N) ?
RS485 tx enable active level (0=low; 1=high): (0) ?
HTTP Port Number : (80) ?
SMTP Port Number : (25) ?
MTU Size (512 - 1400): (1400) ?
TCP Re-transmission Timeout (500 - 4000) (ms): (500) ?
Enable alternate MAC (N) ?
Ethernet connection type: (0) ?

Table of Contents

Other manuals for Lantronix XPort

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix XPort and is the answer not in the manual?

Lantronix XPort Specifications

General IconGeneral
Data Link ProtocolEthernet, Fast Ethernet
Connectivity TechnologyWired
Form FactorEmbedded
CategoryEmbedded Systems
InterfaceSerial
Serial Ports1
Operating Temperature0°C to 70°C

Related product manuals