Important notes for using a Leakwise system
• Refer to the relevant Sensor User Guide for specific information about
sensor certification, installation and operation.
• Consider the following during operation:
1. Beware of high voltage 100 - 240 ±10% VAC inside the enclosure of the
controller unit! Only qualified personnel may service the system.
2. For a controller in a NEMA 7 or Exd enclosure installed in a Hazardous
Area: The enclosure may be opened for service only when the
surrounding atmosphere is known to be non-explosive! Consult your
local Safety Officer!
3. For a controller in a NEMA 4 (IP65) enclosure: Close the cover properly
to attain the weatherproof properties of the enclosure.
For safety: Install a padlock on each quick release latch of enclosure cover!
4. Ambient operating temperature: -20 to +67°C (-4 to +152°F)
5. Maximum relative humidity inside enclosure: 95%, non-condensing.
6. Maximum altitude: 2000 m.