REPEATER POWER CONNECTION
Repeaters should be connected using 1.0 mm pair cabling, if CW1308 is being used then spare pairs can be
doubled-up and/or looped back to form a ring circuit to reduce the voltage drop if necessary.
REPEATER DEPLOYMENT RULES
• A maximum of 3 Repeaters can be configured on an IP-DECT 400 Multi Cell Server - RPN 3
• If you have up to 3 Repeaters on an IP-DECT 400 Multi Cell Server they should be numbered: 67,
131 and 195 i.e. RPN 3 + 64, +128 and +192
• A maximum of 3 Repeaters can be configured on an IP-DECT Base Station - RPN 4/5/6
• If you have up to 3 Repeaters on an IP-DECT Base Station they should be numbered as:
Base Station RPN 4/5/6 +64, +128 and +192
• A maximum of 3 Repeaters can be configured in a chain
• 2 Repeaters cannot have the same number
• See deployment examples below; RPN = the Radio Part Number
Multi-Cell Server/Base is shaded ORANGE Repeaters are shaded GREEN Radio handover BLUE
1 REPEATER DEPLOYMENT
1 Repeater connected directly:
2 REPEATER DEPLOYMENT EXAMPLES
2 Repeaters connected directly:
2 Repeaters connected in a chain: