iComfort Wi-Fi
®
7-Day Programmable Communicating Thermostat
Page 5
Identifying System Devices
From the “system devices” screen, use arrow buttons to scroll to a device; then press the about button. Use the up/down arrows to
scroll through and view additional information about the selected device. When finished viewing, press the back button.
device feature list
Furnace
device description
Equipment Type Name
Furnace
back
Language Support
Equipment Type Name
Unit Model Number
Unit Serial Number
Unit Nominal Capacity
Number of Heating Stages
Heating Capacity by Stage
Indoor Blower CFM Range
Control Software Revision
Control Model Number
about
back next
9:39 am Aug 15, 2012
press 'about' for
more information on
a highlighted device
System
Heat Pump
Furnace
Thermostat
system devices
(returns to
system
devices
screen)
Non-Communicating Equipment — Adding Outdoor Unit, Dehumidifier and Humidifier
NON-COMMUNICATING EQUIPMENT — ADDING OUTDOOR UNIT
System Devices
Add or Remove
Non-communicating
equipment?
yes
nextback
1
non-communicating device list
Not Installed
current value:
back
edit
Not Installed 1 Stage A/C Unit
2 Stage A/C Unit 1 Stage HP Unit
2 Stage HP Unit
Select one
Outdoor Unit Type
cancelsave
To add (or remove) an outdoor unit that is not iComfort
®
you
must be at the “Add or Remove Non-communicating equip
ment?” screen.
1. Press the yes button on this screen (see 1).
2. In the non-communicating device list screen, use the
arrows (2a) to highlight Outdoor Unit Type and press
edit (2b).
3. Touch one of the radio buttons (3a) to select a 1-or
2-Stage AC Unit or a 1-or 2-Stage HP Unit; press save
(3b).
4. Use arrows (4a) to highlight any red colored text in the
device list (e.g. select Outdoor Unit Capacity; text turns
white). Press edit (4b).
5. Use arrows (5a) to make changes; press save (5b).
Change other red settings (if present) using a similar
process.
NOTE - If the defaults are correct, you do not have to make
any changes, but you must press save (5b). When all red text
is gone, the back button will appear; press it to return to the
Add or Remove Non-communicating equipment screen (1).
3b
3a
to add/remove/adjust a device,
select it, then press edit
current value:
non-communicating device list
edit
to add/remove/adjust a device,
select it, then press edit
back
please view and save all
red settings
9:39 am Aug 15, 2012
2 Stage AC Unit
4a
4b
2a
2b
Outdoor Unit Type
Outdoor Unit Capacity
Humidifier
Dehumidifier
Outdoor Unit Type
Humidifier
Dehumidifier
System
Furnace
Outdoor Unit Capacity
Range is 18 to 60
Default is 60 kBTU inc: 1
cancelsave
set-to
5b
5a
60 kBTU
Figure 6. Add Non-Communicating Device — Outdoor Unit