Adjusting System Device Settings
1. Press any component listed under system devices
to change specific communicating equipment para
meters and edit details of devices in the system.
2. Use the arrows to highlight a setting and then press
edit (figure 9A). In the example, the low heating air
flow is changed from the default (400) to 325 (figure
9B). After changing, press save. (note the current
value has changed; figure 9C). Some changes may
affect other settings and, if so, those affected will
appear in red and require changing/saving to clear
the red settings.
3. When finished, press back; equipment parameters
screen then press next. Select tests to run screen
appears; either run tests as before or press skip
tests.
9:39 am Aug 15, 2012
System
edit
back
reset All
current value:
400
Low Heating Airflow
Equipment Name
Heating Airflow Control Type
Low Heating Airflow
High Heating Airflow
High Cooling Airflow
Airflow Profile - Cooling
High HP Airflow
Continuous Indoor Blower Airflow
Heating Indoor Blower OFF Delay
9:39 am Aug 15, 2012
System
edit
back
Reset All
current value:
325
Low Heating Airflow
Equipment Name
Heating Airflow Control Type
Low Heating Airflow
High Heating Airflow
High Cooling Airflow
Airflow Profile - Cooling
High HP Airflow
Continuous Indoor Blower Airflow
Heating Indoor Blower OFF Delay
Low Heating Airflow
Range is 325 to 450 CFM
Default is 400, inc: 25
cancel
save
set-to
325 CFM
Figure 9. Edit Equipment Details
iComfort
®
UNIT CONFIGURABLE SETTINGS
The following tables list the system devices settings available from the installer setup screens.
Table 2. System Devices > System
system devices
System
Heat Pump
Furnace
Thermostat
To adjust a setting,
highlight it, then
press Edit
System
9:39 am Aug 15, 2012
edit
next
back
about
resetAll
Parameter Name: Default Parameter Value Setting Increment
Equipment Name
Press edit to change name (up to 35 charac
ters may be used).
Note: Pressing the resetALL button will re
set all custom parameter settings back to
factory default.
Filter 1 Timer Selection Calendar Time Calendar Time, Run Time
Filter 2 Timer Selection Calendar Time Calendar Time, Run Time
UV Bulb Timer Selection Calendar Time Calendar Time, Run Time
Humidifier Pad Timer Selection Calendar Time Calendar Time, Run Time
PureAir Timer Selection Calendar Time Calendar Time, Run Time
Smooth Setback Recovery Enabled Enabled, Disabled
Electric Heat Control Mode Standard Standard, Evenheat
EvenHeat Discharge Temp 85ºF 85ºF to 130ºF 15ºF
Gas Heat Control Mode Staged
Staged, Variable Capacity, Load Tracking
Variable Capacity
Number of Gas Heating Stages (SLP98V only) (staged selection) 4 1, 2, 3 or 4
Modulating Gas Heating Steady State PI (SLP98V only) Standard Less Aggressive, More Aggressive, Standard
Modulating Gas Heat Step Change PI (SLP98V only) Standard Less Aggressive, More Aggressive, Standard
Modulating HP Heating Cycles Per Hour (XP25 only) 4.0 3.0 to 6.0 0.5
Modulating HP Electric Heating Switching Point (XP25 only) 1.0 0.0 to 2.0 0.25
Modulating HP Heating Steady State PI Gain (XP25 only) Standard Less Aggressive, More Aggressive, Standard
Modulating HP Heating Step Change PI Gain (XP25 only) Standard Less Aggressive, More Aggressive, Standard
Modulating Cooling Steady State PI Gain (XC25 and XP25 only)
Less
Aggressive
Less Aggressive, More Aggressive, Standard
Modulating Cooling Step Change PI Gain (XC25 and XP25 only)
Less
Aggressive
Less Aggressive, More Aggressive, Standard
Modulating Cooling Cycles Per Hour (XC25 and XP25 only) 4.0 3.0 to 6.0 0.5