iComfort Wi-Fi
®
7-Day Programmable Communicating Thermostat
Page 9
Parameter Name: IncrementParameter Value SettingDefault
Auto Changeover - Temp Dead-band 5ºF 3 to 9ºF 1ºF
Max Heat Set point 90ºF 40 to 90ºF 1ºF
Min Cool Set point 60ºF 60 to 99ºF 1ºF
Heat Cool Stages Lock In 60ºF 60 to 99ºF 1ºF
Balance Point Control Disabled Disabled or Enabled —
Humiditrol Comfort Adjust
Maximum
Overcooling
Maximum, Minimum and Midpoint
Overcooling
—
Humidification Control Mode Basic
Display Only, Precision, Precision Dew Point
Control, Basic, Basic Dew Point Control
—
Max Humidification Setpoint 45ºF 15 to 45ºF 1ºF
Auto Changeover - Humidif. Dead-band 5ºF 5 to 10ºF 1ºF
Dew Point Adjustment 0ºF -15ºF to 15ºF 1ºF
Humiditrol and Aux Dehum Min Run Time 15 minutes 5 to 30 minutes 5 minutes
HP Heating Lockout Time (enabled in zoning system) - When heat pump cannot
satisfy demand in a reason time, the control switches to gas heating and lockout
the heat pump for 120 minutes by default.
120 minutes 60 to 240 minutes 30 minutes
Heat Cool Stages Locked In Disabled Enabled, Disabled —
*1st Stage Differential 1.0ºF 0.5 to 3ºF 0.5ºF
*2nd Stage Differential 1.0ºF 0.5 to 8ºF 0.5ºF
*3nd Stage Differential 1.0ºF 0.5 to 8ºF 0.5ºF
Stage Delay Timers Enabled Enabled, Disabled —
*2nd Stage Delay 20 Minutes 5 to 120 Minutes 5 Min
*3rd Stage Delay 20 Minutes 5 to 120 Minutes 5 Min
Electric Heat Stage During Defrost (Used to adjust the number of electric heat
ing elements that will be energized when the heat pump is in defrost mode.)
2 0 to 5 1
Min De-humidification Setpoint 40 50 to 55 RH% 1
Outdoor Temperature Reading Calibration 0ºF -10 to 10ºF 1ºF
Zoning Gas heating DAT Cool down Target 100ºF 80 to 110ºF 1ºF
Zoning Anticipated Discharge Air Temperature Adjustment 60 Seconds 0 to 120 seconds 5 seconds
Zoning Target Supply Air Temp for Cooling 50ºF 50 to 60ºF 1ºF
Zoning Target Supply Air Temp for Gas/Electric Heating 100ºF 100 to 130ºF 5ºF
Zoning Target Supply Air Temp for HP Heating 90ºF 85 to 110ºF 1ºF
Zoning Supply Air Temp Limit for Cooling 40ºF 35 to 45ºF 2ºF
Zoning Supply Air Temp Limit for Gas/Electric Heating 140ºF 140 to 160ºF 5ºF
*Number of stages shown in thermostat is dependent on equipment that is installed. Electric heat will bring on 2 elements at a time if available.
Lock in 2nd stage HP by Outdoor Temp Off
Off, 40ºF (4ºC), 45ºF (7ºC), 50ºF (10ºC), 55ºF
(13ºC)
—
HP Heating Lockout Time 120 Minutes Range is 60 to 240 minutes. 60 Min
Zoning Minimum Zone Run Time 120 Seconds Range is 90 to 600 seconds 30 Sec
Zone 1 First Stage Differential 1.0ºF 0.5 to 3.0ºF 0.5ºF
Zone 2 First Stage Differential 1.0ºF 0.5 to 3.0ºF 0.5ºF
Zone 3 First Stage Differential 1.0ºF 0.5 to 3.0ºF 0.5ºF
Zone 4 First Stage Differential 1.0ºF 0.5 to 3.0ºF 0.5ºF
Zone 1 Continuous Blower CFM
To be determine by equipment capacity.
Zone 2 Continuous Blower CFM
Zone 3 Continuous Blower CFM
Zone 4 Continuous Blower CFM
Zone 1 Cooling CFM
Zone 2 Cooling CFM
Zone 3 Cooling CFM
Zone 4 Cooling CFM
Zone 1 Heating CFM
Zone 2 Heating CFM
Zone 3 Heating CFM
Zone 4 Heating CFM