507343-01
Page 10
Table 3. System Devices > Air Conditioner
system devices
System
Air Conditioner
Furnace
Thermostat
To adjust a setting,
highlight it, then press
Edit
edit
next
back
about
resetAll
Air Conditioner
Parameter Name: Default Parameter Value Setting Increment
Equipment Name Outdoor Unit
Press edit to change name (up to 35 characters may be
used).
Note: Pressing the resetALL button will reset all custom
parameter settings back to factory default.
Compressor Short Cycle Delay 300 Seconds 60 to 300 Seconds 60 Sec
High Normal Cooling Airflow (XC25 only) 1600 450 to 2150 25
Low Normal Cooling Airflow (XC25 only) 750 450 to 2150 25
Dehum Airflow Adjustment Adder 0 0 to 30 1
Table 4. System Devices > Heat Pump
System
Heat Pump
Furnace
Thermostat
system devices
To adjust a setting, high
light it, then press Edit
edit
next
back
about
resetAll
Heat Pump
Parameter Name: Default Parameter Value Setting Increment
Equipment Name Outdoor Unit
Press edit to change name (up to 35 characters may be
used).
Pressing the resetALL button will reset all custom parameter
settings back to factory default.
Note: The resetALL function is required when replacing the
outdoor unit control with a new control part number 103369-04).
Performing the resetALL task will enable new defrost
parameters to be accessible.
Compressor Short Cycle Delay 300 Seconds 60 to 300 Seconds 60 Sec
Compressor Shift Delay On/Off On On, Off
High Normal Cooling Airflow (XP25 only) 1600 450 to 2150 25
Low Normal Cooling Airflow (XP25 only) 750 450 to 2150 25
High Normal HP Heating Airflow (XP25 only) 1600 450 to 2150 25
Low Normal HP Heating Airflow (XP25 only) 750 450 to 2150 25
Dehum Airflow Adjustment Adder 0 0 to 30 1
Defrost Termination Temp 50ºF
50ºF to 100ºF 10ºF
When Outdoor Control 103369-04 or later is used, the follow
ing options are available: 50F (10C), 90F (32C), 70F (21C)
and Max Defrost
Automatic Max Defrost (parameter only available if
using outdoor control 103369-04 or later). See page
32 for further details.
OFF OFF or ON 1
Max Defrost by Weather (parameter only available if
using outdoor control 103369-04 or later). See page
32 for further details.
OFF OFF or ON 1