G71MPP OR SLP98 FURNACE SETTING ADJUSTMENT
If your iComfort Wi-Fi
®
thermostat is being used with either a G71MPP or SLP98 furnace and is set to variable-capacity mode
of operation (the iComfort
®
default with these units), the thermostat's settings for stage timers are ignored (even if shown
enabled in the thermostat). The stage timer will be used on the cooling side for other cooling units except the XC/XP25 where
they are not used. The furnace software sets and controls the firing rates. The only other controlling factor is the stage
temperature differentials. In Load-Tracking Variable Capacity (default for these furnaces), both stage timers and temperature
differentials are ignored.
Replacement iComfort
®
Controls
These kits have been set up for replacement of the iComfort
®
controls. Please note that control kits are unit-specific.
Table 18. Replacement Controls
iComfort
®
Unit
Replacement Kit Catalog
Number
Control Part Number
G71MPP (rev. 03 or later) 65W69 605341-01
SLP98 (rev. 01 or later) 10G43 102813-03
SL280 (rev. 02 or later) 83W88 103130-03
EL296 (rev. 01 or later) 83W88 103130-03
CBX40UHV (rev. 02 or later) AND CBX32MV (rev. 06 or
later)
65W70 605341-02
XC17 11H36 103369-04
XP17 and XP17N 11H36 103369-04
XP19 (rev. 06 or later) 11H36 103369-04
XC21 (rev. 04 or later) 11H36 103369-04
XP21 and XP21N 11H36 103369-04
XP25
11F64
(repair part only)
103686-03
XC25
11F64
(repair part only)
103686-03