Page 62
Table 10. Alert Codes and Troubleshooting
Critical alerts are displayed on the Home screen, in the Home
owner alert button, and in the Installer alert button. Minor and
moderate alerts are found only in the Installer alert button.
Alert
Code
PRIORITY
CONDITION
APPLICABLE
SYSTEM
COMPONENTS
ALERT TEXT
COMPONENT OR SYSTEM OPERA
TIONAL STATE AND TROU
BLESHOOTING TIP
HOW TO CLEAR
ALERT CODE
429
Moderate /
Critical
Outdoor unit
The inverter has detected a DC
link low voltage condition
.
On a call for compressor opera
tion, if DC link power in inverter
does not rise above 180 VDC for
2- and 3 -ton models, 250 VDC
for 4- and 5-ton models within 30
seconds, the control will display a
moderate code.
If condition is detected, outdoor
unit will stop (compressor and
fan) – moderate condition.
An anti-short cycle timer is initiat
ed. If condition occurs 10 times
within a 60 minute rolling time pe
riod, system will lock out and dis
play alert code 429 – critical
condition.
The outdoor control anti-short cy
cle timer will time out and the unit
will recycle the demand.
Replace outdoor inverter.
Automatically clears
when the system de
tects that the issue no
longer exists.
430
Moderate /
Critical
Outdoor unit
Compressor start-up failure
If condition is detected, outdoor
unit will stop (compressor and
fan) – moderate condition.
Anti-short cycle is initiated.
If condition occurs 10 times within
an hour, system will lockout –
critical condition.
To clear, disconnect
power to outdoor unit
and restart.
431
Moderate /
Critical
Outdoor unit
The inverter has detected a PFC
circuit over-current condition.
Error occurs when PFC detects
an over current condition of 100A
peak.
If condition is detected, outdoor
unit will stop (compressor and
fan) – moderate condition.
Anti-short cycle timer is initiated.
If condition occurs 10 times within
an hour, system will lockout –
critical condition.
To clear, disconnect
power to outdoor unit
and restart.
432
Moderate /
Critical
Outdoor unit
The inverter has detected a DC
link high voltage condition.
Error occurs when the DC link ca
pacitor voltage is greater than
480VDC.
If condition is detected, outdoor
unit will stop (compressor and
fan) – moderate condition.
Anti-short cycle timer is initiated.
If condition occurs 10 times within
an hour, system will lockout –
critical condition.
To clear, disconnect
power to outdoor unit
and restart.