Commissioning
Using the keypad XT EMZ9371BC − Parameter setting
7
EDK82EV113 DE/EN/FR 8.1
131
L
Change and save parameters
All parameters for controller setting or monitoring are saved in codes. The codes are
numbered and labelled in the documentation with a "C". Some codes store the parameters
in numbered subcodes", so that a clear parameter setting is ensured (e. g.: C0517 User
menu).
The codes are described in detail in the system manual of the drive controller.
) Note!
Your settings in the menus are always stored in the parameter set 1.
If you want to store settings in the parameter set 2, 3 or 4, two menus can be
used:
l In menu 2 "Code list" it is possible to access to all available codes.
l In menu 7 "Param managm" it is possible to copy parameter set 1 into the
oter parameter sets.
– Please note, that with copying the "own basic setting" will be
overwritten by the settings of parameter set 1!
Step Keys Action
1. Select menu
Select the desired menu with arrow keys
2. Change to the code level
Display of first code in the menu
3. Select code or subcode
Display of current parameter value
4. Change to parameter level
5. If SHPRG is displayed, inhibit controller
The drive is idling
6.
Change parameters
A
Move cursor under the digit to be changed
B
Change digit
Change digit quickly
7.
Accept changed parameter
Display of SHPRG or SHPRG
Confirm change to accept parameter
Display "OK"
Display
− The parameter was accepted immediately
8. If necessary, enable controller
The drive should be running again
9.
Change to the code level
A
Display of operation level
B
Display of the code with changed parameters
10. Change further parameters Restart "loop" at step 1. or step 3.