8
Fault detection and elimination
Fault messages
EDK82EV113 DE/EN/FR 8.1
L
156
Keypad RemedyCauseErrorPC
1)
Pr
75 Faulty parameter
transfer when using
the keypad
All parameter sets are defective
It is absolutely necessary to repeat the data
transfer or load the Lenze setting before
enabling the controller.
Pr1
72 Wrong PAR1 transfer
when using the
keypad.
PAR1 is defective.
Pr2
73 Wrong PAR2 transfer
when using the
keypad.
PAR2 is defective.
Pr3
77 Wrong PAR3 transfer
when using the
keypad.
PAR3 is defective
Pr4
78 Wrong PAR4 transfer
when using the
keypad.
PAR4 is defective
Pr5
79 Internal fault Contact Lenze
Pt5
81 Time fault during
parameter set transfer
Data flow from keypad or PC
interrupted, e. g. keypad was
disconnected during transfer
It is absolutely necessary to repeat the data
transfer or load the Lenze setting before
enabling the controller.
rSt
76 Faulty auto−TRIP reset More than 8 fault messages in 10
minutes
Depends on the error message
sd5
85 Wire breakage analog
input 1
Current at analog input < 4 mA at
setpoint range 4 ... 20 mA
Close circuit at analog input
sd7
87 Wire breakage analog
input 2
1)
LECOM−fault number, display in parameter setting program Global Drive Control (GDC)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com