Mains connection
14
MA8200MOT DE/EN/FR 3.0
Stop!
l
Connect the controller only to a mains voltage between 180 V ... 264 V! Higher mains
voltages will destroy the controller!
l
The discharge current to earth is higher than 3.5 mA. Therefore permanent fixed
installation is required.
8200mot056
Abb. 1-10
X1
X1
PE
PE
L1
L1
N
L2
1/N/PE AC 240 V
2/PE AC 240 V
BR1
BR1
BR2
BR2
L1
L1
L2/N
L2/N
L3
L3
L3 Terminal L3 is not assigned to any function. It can, for instance, be used as support terminal.
BR1, BR2 Connection terminals for brake resistor (optionally)
Ensure correct PE connection of the mains cable!