Braking operation
Braking operation with external brake resistor
Wiring of brake resistor
8
101
EDS84ABD302 EN 4.0
Wiring principle
R
B
+UG RB
< 0.5 m
PE
R
B
+UG RB
<5m
PE
PES
PES
ERBG_BLD ERBG_BLD02
Fig. 8-2 Wiring of a brake resistor to the controller
PES HF-shield termination by PE connection via shield clamp
+UG, RB Terminals of the brake resistor
c
Supply cable to the controller with twisted pair wiring
d
Supply cable to the controller using shielding
(to be integrated e.g. into the latch circuit of the mains contactor of the supply)