EasyManua.ls Logo

Lenze 8400 motec - Initial Switch-On

Lenze 8400 motec
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning
Initial switch-on
28
Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 4.0 - 09/2013
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.4 Initial switch-on
Establishing communication
To establish a communication, the Inverter Drive must be supplied with mains voltage.
For AS-i communication, the Communication Unit has to be supplied with voltage. If this is not
the case, the error message "CE04: MCI communication error" (error no. 01.0127.00002) is
output.
•The Voltage supply
( 23) via the AS-i bus cable serves to maintain the AS-i communication in
case of a main supply failure.
During mains connection, all parameters (codes) are read.
Addressing can be carried out automatically via the master, an external addressing unit or
manually via codes in the »Engineer«.
Addressing the AS-i slaves
( 26)

Table of Contents

Other manuals for Lenze 8400 motec

Related product manuals