13 Parameter reference
13.2 Parameters of the communication module for slot MXI1
99
Lenze · E94AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 12/2013 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13863
C13870
Parameter | Name:
C13863 | Ethernet Port
Data type: UNSIGNED_16
Index: 10712 = 0x29D8
Display of the baud rate currently used on the Ethernet connections
Selection list (read only)
0 Nonexistent
1 10 Mbps/Half Duplex
2 10 Mbps/Full Duplex
3 100 Mbps/Half Duplex
4 100 Mbps/Full Duplex
5 Reserved
6 Reserved
Subcodes Info
C13863/1 Ethernet port X233 link state
C13863/2 Ethernet port X234 link state
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13870 | CIP Connections State
Data type: UNSIGNED_16
Index: 10705 = 0x29D1
Display of the current CIP connection status
Selection list (read only)
0 Nonexistent
3 Established
4 Timed Out
Subcodes Info
C13870/1 Status of CIP connection 1
... ...
C13870/8 Status of CIP connection 8
Read access Write access CINH PLC STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT